Air to air heat pump GREE Amber Nordic 7.03/7.03 KW
Air to air heat pump GREE Amber Nordic 7.03/7.03 KW
Code: GWH24YE-S6DBA1A/I+GWH24YE-S6DBA2A/OUseful performance coefficient SCOP up to 5.7;
Energy efficiency class A+++/A+++;
Effectively heats up to -30C outside air temperature;
Cooling down to -18C outside air temperature;
Protection of the outer part against freezing;
+8C temperature maintenance function;
"I-Feel" function;
New patented, two-stage compressor;
Wi-Fi control by smartphone;
Extremely quiet operation up to 18 dB(A);
The wall-mounted control panel XK76 is equipped additionally;
Warranty 3 years.ProducerGREE-
Air to air heat pump Amber Nordic keeps a high heating coefficient even when outdoor temperature drops to -30°C. With G10 inverter technology the heat pump works much quieter and consumes less electricity.
Description:
I feel function - a sensor on the remote control measures the ambient temperature and sends a signal to the heat pump. The heat pump sets the temperature and air flow rate for maximum comfort in that area;
+ 8°C indoor temperaturew mode;
With integrated Wifi module.
Effectively heats when the outdoor temperature drops to -30 ° C and cools when the outdoor temperature drops to -18°C.Technical characteristics:
Power (cooling), kW 7.03 (2.0-9.0) Power (heating), kW 7.03 (2.0-9.5) Nom. el. power (min.-max.) during cooling, kW 1.85 (0.45-3.7) Nom el. power (min.-max.) during heating, kW 1.75 (0.38-3.8) Maximum current (cooling/heating), A 11/10.76 SEER/SCOP 6.5/5.3 Effective efficiency EER/COP 3.8/4.0 Energy efficiency class (cooling/heating) A++/A+++ Annual electricity consumption (cooling/heating), kWh 377/1849 Air volume (max/avg/min), m3/h 1200/1050/950/900/850/900/750 Noise level of the inner part (max/avg/min), dB(A) 50/46/43/41/39/37/35 Noise level of the external part (max/avg/min), dB(A) 58 Dimensions (inner part), mm 327x1101x249 Dimensions (external part), mm 790x980x427 Weight (internal/external part), kg 16.5/65 Pipe connection diameter (liquid/gas), inches 1/4"/ 5/8" Pipeline length (min./max.), m 3/50 Maximum height difference, m 30 Operating temperature limits during cooling (min./max.), C -18~52 Operating temperature limits during heating (min./max.), C -30~24 Operating temperature limits of the internal part (min./max.), C 16~30 Compressor Type rotary two-stage Freon R32 Freon quantity/replenishment from, kg/m 2.0/7.5 Amount of freon addition, g/m 50 Power supply/supply to the part, V-Ph-Hz 220-1-50 to the outer part Cable between inner and outer part, mm2 4x1.5 Input wire, mm2 3x1.5 Automatic circuit breaker, A 25